General Information

Provider

CyrusOne

Colo Space

220,000 SF

Airport

N/A

Year Built

N/A

Security

On-site

Uptime

100% uptime service level agreement on power and cooling

Hyperscale

Enabled

Retail

Available

Wholesale

Available

Interconnectivity

Available

Overview

Located in Durham, North Carolina, CyrusOne's DUR1 data center is a multi-phase development consisting of 420,000 data center square feet. The facility is designed, built and commissioned to meet the most stringent enterprise standards, and benefits from some of the lowest all-in utility rates in the nation, at $0.045 kWh. DUR1 Data Center is in Research Triangle Park, North Carolina, home to numerous high-tech companies, world class universities, research facilities and an educated workforce drawn to the high-tech enterprises of the area. It is located close to Raleigh-Durham International Airport, with easy access to major highways and rail.

Certifications

Full sales tax exemption on all tenant IT equipment and electricity consumption

Power & Infrastructure

Power Density

Up to 200+ W per square foot, Power densities as high as 200 kw per rack

Utility Feeders

100 KV Transmission Class substation with 230 KV switching from Duke Energy, Utility power delivered by two geographically diverse substations

UPS

1.2MW UPS modules (Toshiba/Mitsubishi). N+2 ISO-redundant failover topology (Tier III+ topology. N+2 UPS system redundancy)

Standby Power

Eight (8) 2800 kW prime rated (3000 kW standby rated) Caterpillar C-175 generators (N+2 engine generator redundancy)

Cooling

42-inch raised white floor design, 24-foot ceiling height from data center floor, utilizing Leibert 60-ton CRAH units with electronically commutated (EC) variable-speed fans (N+2 mechanical plant redundancy, N+2 redundant Trane chillers with rapid restart and adaptive controlled microprocessors)

Flood Zone

Zone X flood zone rating (low risk)

Seismic Rating

Zone 1-2 seismic zone rating (low /moderate risk)

Fire Suppression

Double-interlocking pre-action sprinkler in computer rooms and electrical rooms. Wet pipe in office and storage areas

Fire Detection

Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zone-based dual-action interlocking dry-pipe pre-action system

Amenities

  • 24/7 year-round staffed NOCC and remote hands support
  • Dedicated data center suites available
  • Perimeter fence
  • Full suite of Remote Hands Services
  • Office Space
  • Storage Space
  • Various restaurants and hotels nearby hoteling space
  • Video surveillance and recording of the exterior and interior with 90 days digital archiving
  • Dual authentication entry into building and data halls; biometric and key card security for rigid access control
  • 24/7 year round Security Personnel
  • Two factor biometric authentication required to access building
  • Three (3) remote 20,000 gallon tanks (with min. 48-hour capacity)

Other Information

Network Providers

Carrier-neutral

Media

No media available.

Contact Raleigh DUR1 Data Center

Complete the form to get your information reviewed by Raleigh DUR1 Data Center